Service manual
5
RRP: Power Supply
5-23
Removal and Replacement Procedures (RRPs)
RRP: Power Supply
Use the following procedures toremove or replace apower supply. A
list of tools required is provided.
Tools Required The following tools are required to perform these procedures.
• Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
• Standard flat-tip screwdriver.
• ESD grounding cable and wrist strap.
Removal To remove a power supply:
1. If the director is installed in a stand-alone configuration, go to
step 2. If the director is rack-mounted, perform one of the
following:
— If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16" door tool into
the socket hole at the right top of the rear door. Turn the tool
counter-clockwise to unlock and open the door.
— If the director is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet rear door as directed by
the customer representative.
ATTENTION! To avoidcausing machine errorsor damagewhileworkingon
the director, follow ESD procedures by connecting a grounding cable to the
director chassis and wearingan ESD wrist strap.
2. Follow ESD procedures by attaching a wrist strap to the director
chassis and your wrist (Figure 5-1).
3. Identify the defective power supply from the extinguished green
PWR OK LED on the supply or failure information at the
management server Hardware View.
4. Useaflat-tipscrewdrivertoreleasethehandleatthetopofthe
power supply.