RRP: Optical Transceiver (SFP and XFP)
5-17
Removal and Replacement Procedures (RRPs)
RRP: Optical Transceiver (SFP and XFP)
Use the following procedures to remove or replace an SFP or XFP
optical transceiver from a UPM or XPM card. A list of tools required
is provided.
Tools Required The following tools are required to perform these procedures.
Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
ESD grounding cable and wrist strap.
Fiber-optic protective plug (provided with the director).
Protective cap (provided with the fiber-optic jumper cable).
Fiber-optic cleaning kit.
Removal To remove an SFP or XFP optical transceiver:
1. Notify the customer that the port with the defective transceiver
will be blocked. Ensure the customer system administrator sets
the attached device offline.
2. If the director is installed in a stand-alone configuration, go to
step 3. If the director is rack-mounted, perform one of the
following:
If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16" door tool into
the socket hole at the right top of the rear door. Turn the tool
counter-clockwise to unlock and open the door.
If the director is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet rear door as directed by
the customer representative.
3. To remove a rear-mounted FRU, remove the RFI shield.
4. Identifythe defective port transceiverfrom the amberLED on the
port card or failure information at the management server Port
Card View.
5. Block communication to theport (Blockingand UnblockingPorts on
page 4-27).
6. Follow ESD procedures by attaching a wrist strap to the director
chassis and your wrist (Figure 5-1).