Service manual
5
5-10
Intrepid® 6140 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
— 422 - CTP firmware synchronization complete (only if the
firmware versions on the two CTP cards are different).
Iftheeventcodesdonotappearinthelog,gotoChapter 3,
MaintenanceAnalysisProcedures(MAPS)to isolate the problem.
11. Perform one of the following to verify CTP card operation:
— If at the management server, open the Hardware View and
observe the CTP card graphic to ensure no alert symbols
appearthat indicate afailure(yellow triangleor red diamond).
Ifa problemis indicated, goto Chapter3, Maintenance Analysis
Procedures (MAPS) to isolate the problem.
— If at a web browser connected to the EFCM Basic Edition
interface, open the Switch tab at the View panel and ensure no
amber LEDs illuminate that indicate a CTP card failure. If a
problem is indicated, go to Chapter 3, Maintenance Analysis
Procedures (MAPS) to isolate the problem.
12. Perform the data collection procedure (Collecting Maintenance
Data on page 4-32).
13. If the customer requests the replacement CTP card be set as the
active card, perform a FRU switchover. At the Hardware View,
right-click the graphic representing the replacement card to open
amenu,thenselectSwitchover.
14. Perform one of the following to clear the system error (ERR) LED:
— If at the management server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click the Clear System Error Light menu selection.
— If at a web browser connected to the EFCM Basic Edition
interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with
the Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
15. If necessary, close and lock the equipment cabinet door.