Service manual
5
5-2
Intrepid® 6140 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
Procedural Notes
NOTE: The screens in this manual may not match the screens on your server
and workstation. The title bars have been removed and the fields may
contain data that does not match the data seen on your system.
The following procedural notes are referenced as applicable. The
notes do not necessarily apply to all procedures in the chapter.
1. Before performing a FRU repair, read the removal and
replacement procedures for that FRU carefully and thoroughly to
familiarize yourself with the procedures and reduce the
possibility of problems or customer down time.
2. Follow all electrostatic discharge (ESD) procedures, DANGER
and CAUTION statements, and statements listedin the preface of
this manual.
3. After completing the steps of a detailed procedure that is
referenced from another procedure, return to the initial
(referencing) procedure and continue to the next step of that
procedure.
4. After completing a replacement procedure, clear the event code
reporting the failure and the event code reporting the recovery
from the Event Log (at the management server or EFCM Basic
Edition interface), and extinguish the amber system error light-
emitting diode (LED) at the director front bezel.