Service manual
4
Managing Configuration Data
4-51
Repair Information
2. Set the director offline (SettingtheDirectorOnlineorOfflineon
page 4-36).
3. At the Element Manager application, select Backup & Restore
Configuration from the Maintenance menu. The Backup and Restore
Configuration dialog box displays (Figure 4-18).
4. Click Restore.AWarning dialog box displays, indicating the
existing configuration file is to be overwritten.
5. Click Ye s .ARestore dialog box displays, indicating the restore is in
progress.
6. When the operation finishes, the Restore dialog box displays a
Restore complete message. Click Close to close the dialog box.
Reset Configuration Data (Element Manager Application)
When configuration data is reset to factory defaults, the director
defaults to the factory-set IP address and all optional features are
disabled. To reset configuration data to the factory defaults:
1. Notify the customer that the director will be set offline. Ensure
that the system administrator quiesces Fibre Channel traffic
through the director and sets attached devices offline.
2. Set the director offline (SettingtheDirectorOnlineorOfflineon
page 4-36).
3. At the SAN management application physical map, right-click
the icon representing the director for which a configuration file is
to be reset to factory defaults, then select Element Manager from
the pop-up menu. The application opens.
4. At the Element Manager application, select Reset Configuration
from the Maintenance menu. The Reset Configuration dialog box
displays (Figure 4-19).
Figure 4-19 Reset Configuration Dialog Box