Intrepid® 6140 Director Installation and Service Manual
Repair Information
The director-to-management server Ethernet link drops
momentarily and the following occur at the Hardware View:
As the network connection drops, the Intrepid 6140 Status
table turns yellow, the Status field displays No Link,and
the State field displays Link Timeout.
The status bar at the bottom of the window displays a grey
square, indicating director status is unknown.
Illustrated FRUs disappear, and appear again as the
connection is re-established.
Cleaning Fiber-Optic Components
Perform this procedure as directed in this publication and when
connecting or disconnecting fiber-optic cables from port optical
transceivers.
Tools required:
ESD grounding cable and wrist strap
Fiber-optic cleaning kit with:
Oil-free compressed air or HFC-134a aerosol duster
Alcohol-soaked cleaning pads.
Procedure:
CAUTION
Wear eye protection when using an aerosol duster.
To clean fiber-optic components:
ATTENTION! To avoidcausing machine errorsor damagewhileworkingon
the director, follow ESD procedures by connecting a grounding cable to the
director chassis and wearingan ESD wrist strap.
1. Follow ESD procedures by attaching a wrist strap to the director
chassis and your wrist.
2. Disconnect the fiber-optic cable from the port. Use an aerosol
duster to blow away any contaminants from the connector (part
A of Figure 4-13).