Intrepid® 6140 Director Installation and Service Manual
Repair Information
c. Click OK at the bottom of the page. The port resets and the
message Your changes have been successfully activated.
appears.
8. Notify the customer that the test is complete and the attached
device can be set online.
External Loopback Test (EFCM Basic Edition)
To perform an external loopback at the EFCM Basic Edition interface:
1. Notify the customer that a disruptive external loopback test will
be performed and that the attached device must be disconnected.
2. Disconnect the fiber-optic jumper cable from the port to be tested.
3. Depending on the port technology, insert a singlemode or
multimode loopback plug into the port receptacle.
4. At the EFCM Basic Edition interface, select Ports and Diagnostics
from the Maintenance menu at any view. The Diagnostics View
displays (Figure 4-6).
5. Type the port number to be tested in the Targeted Port Number
field.
6. At the Diagnostic Test listbox,selecttheExternal Loopback option.
7. Click Start. The test begins and:
a. The Diagnostics View changes to a Diagnostics -Executing View.
b. The message Diagnostics Time Remaining: xx appears,
where xx are the seconds remaining in the test. The test takes
approximately 30 seconds.
NOTE: Click Stop at any time to stop the loopback test.
8. When the test completes, the Diagnostics - Executing View reverts
to the Diagnostics View. Test results appear as Passed, Failed, or
Test Incomplete in the message area of the view.
9. Remove the loopback plug and reconnect the fiber-optic jumper
cable from the device to the port.
10. Reset the tested port:
a. Select Ports and Reset from the Maintenance menu at any view.
The Reset View displays.