Service manual
4
4-24
Intrepid® 6140 Director Installation and Service Manual
Repair Information
c. A red progress bar (indicating percent completion) travels
from left to right across the Completion Status field.
10. When the test completes, results appear as Port xx: Passed! or
Port xx: Failed! in the message area of the dialog box.
11. When finished, click Cancel to close the Port Diagnostics dialog
box.
12. Remove the loopback plug and reconnect the fiber-optic jumper
cable from the device to the port.
13. Reset the port:
a. At the Hardware View, right-click the port graphic. A pop-up
menu appears.
b. Select Reset Port. A message box displays, indicating a link
reset will occur.
c. Click OK.Theportresets.
14. Notify the customer the test is complete and the device can be
reconnected to the switch and set online.
Internal Loopback Test (EFCM Basic Edition)
To perform an internal loopback at the EFCM Basic Edition interface:
1. Notify the customer that a disruptive internal loopback test will
be performed. Ensure the system administrator quiesces Fibre
Channel frame traffic through the port and sets attached device
offline.
NOTE: An optical transceiver (SFP or XFP) must be installed in the port
during the test. A device can remain connected during the test.
2. At the EFCM Basic Edition interface, select Ports and Diagnostics
from the Maintenance menu at any view. The Diagnostics View
displays (Figure 4-6).