Service manual

4
4-16
Intrepid® 6140 Director Installation and Service Manual
Repair Information
Port WWN - The Fibre Channel WWN of the port.
Attached Port WWN - The Fibre Channel WWN of the device
attached to the port.
Block Configuration - A user-configured state for the port
(Blocked or Unblocked).
10 - 100 km Configuration - Theuser-configuredstatefor
extended distance operation (On or Off).
Rx BB_Credits Configured - The user-defined number of receive
BB_Credits allocated to the port.
NPIV Login Limit Configured - With N_Port ID virtualization
(NPIV) enabled, the user-defined maximum number of virtual
addresses assigned to the physical port.
Logged in IDs - The number of virtual addresses logged in to the
physical port.
LINAlerts Configuration - A user-specified statefor theport (On
or Off).
FAN Configuration - A user-configured state for FAN
configuration (Enabled or Disabled).
Beaconing - User-specified for the port (On or Off). When
beaconing is enabled, a yellow triangle appears adjacent to the
status field.
Link Incident -If no link incidents are recorded, None appears in
the status field. If a link incident is recorded, a summary appears
describing the incident, and a yellow triangle appears adjacent to
the status field.
Operational State - The state of the port (Online, Offline,
Beaconing, Invalid Attachment, Link Incident, Link Reset, No Light,
Not Operational, Port Failure, Segmented E_Port,orTesting). A
yellow triangle appears adjacent to the status field if the port is in
a non-standard state that requires attention. A red and yellow
diamond appears adjacent to the status field if the port fails.
Reason - A summary appears describing the reason if the port
state is Segmented E_Port, Invalid Attachment,orInactive.Forany
other port state, the reason field is blank or N/A.
Threshold Alert- If a threshold alert exists for the port, an alert
indicator (yellow triangle) and the configured name for the alert
appear.