Service manual

4
4-12
Intrepid® 6140 Director Installation and Service Manual
Repair Information
Element Manager Application Diagnostics
To obtain port operational information at the Element Manager
application, inspect parameters at the:
Port List View.
Performance View.
Port Properties dialog box.
Port Technology dialog box.
Link
Incident
Off Off Yellow Triangle A link incident occurred on the port. The alert symbol
appears at the
Port Card View
,
Port List View
, and
Hardware View
.
Link Reset Off Off Yellow Triangle The director and attached device are performing a link
reset operation to recover the link connection. This is a
transient state that should not persist.
No Light Off Off None No signal (light) is received by the director port. This is a
normal condition when there is no cable attached to the
port or when the attached device is powered off.
Inactive On Off Yellow Triangle The port is inactive. The reason appears in the
Reason
field at the
Port Properties
dialog box.
Not
Installed
Off Off None An optical transceiver is not installed in the director port.
Not
Operational
Off Off Yellow Triangle The director port is receiving the not operational
sequence (NOS) from an attached device.
Port Failure Off On Red and Yellow
Blinking Diamond
The director port failed and requires service.
Segmented
E_Port
On Off Yellow Triangle The E_Port is segmented, preventing two connected
directors from joining and forming a multiswitch
fabric.The reasons for the segmentation display in the
Reasons
field of the
Port Properties
dialog box.
Testing Off
On
Blinking
Blinking
Yellow Triangle
Yellow Triangle
The port is performing an internal loopback test.
The port is performing an external loopback test.
Table 4-2 Port Operational States (
continued
)
Port
State
Green
LED
Amber
LED
Alert
Symbol
Description