Service manual

4
4-6
Intrepid® 6140 Director Installation and Service Manual
Repair Information
Date/Time - The date and time the FRU was inserted or removed.
FRU - An acronym representing the FRU type.
Position - A number representing the FRU chassis position. The
chassis (slot) position for a nonredundant FRU is 0.Thechassis
positions for redundant FRUs are 0 and 1.
Action - The action performed (Inserted or Removed).
Part Number - The part number of the inserted or removed FRU.
Serial Number - The serial number of the inserted or
removed FRU.
Link Incident Log
The Link Incident Log records Fibre Channel link incident events and
causes.
The log describes:
Date/Time - The date and time the link incident occurred.
Port - The port number that reported the link incident.
Link Incident -A brief description of the link incident and cause,
including:
—Implicitincident.
Bit-error threshold exceeded.
Lossofsignalorlossofsynchronization.
Not-operational primitive sequence received.
Primitive sequence timeout.
Invalid primitive sequence received for current link state.
See MAP 0500: Port Failure or Link Incident Analysis on page 3-34 for
corrective actions.
Port Threshold Alert Log
The Port Threshold Alert Log records a history of threshold alert
notifications.
The log describes:
•Date/Time- The date and time stampfor whenthe alertoccurred.
•Name- The name for the alert as configured through the
Configure Threshold Alerts dialog box.