Service manual
3-46
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
↓ The problem is transient and the product port is operational.
Exit MAP.
23
Clean fiber-optic components.
a. Inform the customer the port will be blocked. Ensure the system
administrator quiesces Fibre Channel frame traffic and sets
attached devices offline.
b. Block the port (
Blocking and Unblocking Ports
on page 4-27).
c. Clean fiber-optic connectors (
Cleaning Fiber-Optic Components
on page 4-40).
d. Unblock the port (
Blocking and Unblocking Ports
on page 4-27).
e. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
↓ The product port is operational. Exit MAP.
24
Disconnect the fiber-optic jumper cable from the port and connect the
cabletoaspareport.
Is a link incident reported at the new port?
YES NO
↓ The port reporting the problem is causing the link incident.
This indicates port degradation and a possible pending
failure. Go to step 20.
25
Ensure the attached fiber-optic jumper cable is not bent and
connectors are not damaged. If the cable is bent or connectors are
damaged:
a. Inform the customer the port will be blocked. Ensure the system
administrator quiesces Fibre Channel frame traffic and sets
attached devices offline.
b. Block the port (
Blocking and Unblocking Ports
on page 4-27).
c. Remove and replace the fiber-optic jumper cable.
d. Unblock the port (
Blocking and Unblocking Ports
on page 4-27).
Was the maintenance action successful?