Service manual
3-40
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
Contact the next level of support. Exit MAP.
11
A connection is not allowed because of a switch binding or exchange
security attribute (ESA) feature mismatch. Switch binding parameters
must be compatible for both fabric elements. At the EFCM Basic
Edition interface or Element Manager, ensure switch binding is
enabled, the connection policy is compatible, and switch membership
lists are compatible for both elements.
• EFCM Basic Edition - Refer to the
McDATA EFCM Basic Edition
User Manual
(620-000240) for instructions.
• Element Manager - Refer to the
McDATA Intrepid 6140 and
6064 Directors Element Manager User Manual
(620-000153).
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
12
A connection is not allowed because of a fabric binding mismatch.
Fabric membership lists must be compatible for both elements. At the
EFCM Basic Edition interface or SAN management application,
ensure fabric binding is enabled and fabric membership lists are
compatible for both elements.
• EFCM Basic Edition - Refer to the
McDATA EFCM Basic Edition
User Manual
(620-000240) for instructions.
• SAN management application - Refer to the
SANavigator
Software Release 4.2 User Manual
(621-000013) or
EFC
Manager Software Release 8.7 User Manual
(620-000170) for
instructions.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
13
A connection is not allowed because of a SANtegrity authentication
failure. At the EFCM Basic Edition interface or Element Manager,