Service manual

3-38
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
The product is configured to operate in Open Fabric 1.0 mode
and is connected to a legacy McDATA switch at the incorrect
exchange link parameter (ELP) revision level.
The product is configured to operate in Open Fabric 1.0 mode
and is connected to a non-McDATA switch at the incorrect ELP
revision level.
The product is configured to operate in McDATA Fabric 1.0
mode and is connected to a non-McDATA switch.
Reconfigure the operating mode:
a. Set the product offline (
Setting the Director Online or Offline
on
page 4-36).
b. For the product reporting the problem:
EFCM Basic Edition - Select
Switch
and
Fabric Parameters
from the
Configure
menu at any view. The
Fabric
Parameters View
displays.
Element Manager - Select
Operating Parameters
and
Fabric Parameters
from the
Configure
menu at any view.
The
Configure Fabric Parameters
dialog box displays.
c. Select McDATA Fabric 1.0 or Open Fabric 1.0 from the
Interop
Mode
drop-down list.
—SelectMcDATA Fabric 1.0 if the product is attached
only
to
other McDATA directors or switches operating in McDATA
Fabric 1.0 mode.
—SelectOpen Fabric 1.0 if the product is attached to
directors or switches produced by open-fabric compliant
original equipment manufacturers (OEMs).
d. Click
OK
or
Activate
.
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
7
A loopback (wrap) plug is connected to the port with no diagnostic
running. Remove the plug from the port receptacle. If directed by the
customer,connectafiber-opticjumpercableattachingadevicetothe
product.