Service manual

Maintenance Analysis Procedures
3-37
Maintenence Analysis Procedures
5
A connection is not allowed because of a conflict with the configured
port type. An expansion port (E_Port) is cabled to a Fibre Channel
device or a fabric port (F_Port) is cabled to a director or fabric switch.
a. For the product reporting the problem:
EFCM Basic Edition - Select
Ports
and
Basic Info
from the
Configure
menu at any view. The
Basic Information View
displays.
Element Manager - Select
Ports
from the
Configure
menu
at any view. The
Configure Ports
dialog box displays.
b. If necessary, use the vertical scroll bar to display the information
row for the port indicating an invalid attachment.
c. Select (click) the
Type
field and configure the port as follows:
Select fabric port (F_Port) if the port is cabled to a device.
Select expansion port (E_Port) if the port is cabled to a
director or switch (ISL).
d. Click
OK
or
Activate
.
e. Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
6
An ISL connection is not allowed because one of the following
mode-mismatch conditions was detected:
The product is configured to operate in Open Fabric 1.0 mode
and is connected to a fabric element not configured to Open
Fabric 1.0 mode.
0F Unauthorized switch binding WWN. Go to step 11.
10 Authentication failure Go to step 13.
11 Fabric mode mismatch. Go to step 6.
Table 3-11 Invalid Attachment Reasons and Actions (Continued)
Byte 4 Invalid Attachment Reason Action