Service manual
Maintenance Analysis Procedures
3-35
Maintenence Analysis Procedures
2
Table 3-10 lists link incident messages and MAP steps.
3
The eight-byte (16-digit) worldwide name (WWN) is not valid or an
unconfigured nickname was used.
a. For the product reporting the problem:
— EFCM Basic Edition - Select
Node List
from the
Product
menu at any view. The
Node List View
displays.
— Element Manager - Select the
Node List
tab at any view.
The
Node List View
displays.
b. At the
Port WWN
column, inspect the WWN assigned to the port
or attached device.
586 Invalid primitive sequence received for current link state. Go to step 22.
800 High temperature warning (port card thermal sensor). Go to step 21.
801 Critically hot temperature warning (port card thermal
sensor).
Go to step 21.
802 Port card shutdown due to thermal violation. Go to step 21.
Table 3-10 Link Incident Messages
Explanation Action
Link interface incident - implicit incident. Go to step 22.
Link interface incident - bit-error threshold exceeded. Go to step 22.
Link failure - loss of signal or loss of synchronization. Go to step 22.
Link failure - not-operational primitive sequence (NOS) received. Go to step 22.
Link failure - primitive sequence timeout. Go to step 22.
Link failure - invalid primitive sequence received for current link state. Go to step 22.
Table 3-9 MAP 500: Event Codes (Continued)
Event
Code
Explanation Action