Service manual

3-32
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
YES NO
Contact the next level of support. Exit MAP.
The product is operational. Exit MAP.
4
An intermittent synchronous dynamic random access memory
(SDRAM) problem may indicate a CTP card failure.
Is the event code a recurring problem?
NO YES
A CTP card failure is indicated. Go to step 6.
Perform a data collection (
Collecting Maintenance Data
on
page 4-32) and contact the next level of support. Exit MAP.
5
An intermittent thermal problem may indicate a CTP card failure.
Reset the director (
IML, IPL, or Reset the Director
on page 4-38).
Was the maintenance action successful?
NO YES
The product is operational. Exit MAP.
6
Visual inspection (amber LED illuminated) or event codes indicate a
CTP card failed.
Replace the CTP card (
RRP: CTP Card
on page 5-6).
The procedure is concurrent and performed while the product is
operational.
Perform a data collection as part of FRU replacement (
Collecting
Maintenance Data
on page 4-32).
NOTE: Do not remove a CTP card if the backup CTP card is not fully
operational and director power is on; otherwise the director IP address,
configuration data, and other operating parameters will be lost.
Was the maintenance action successful?
YES NO
Contact the next level of support. Exit MAP.
The product is operational. Exit MAP.