Service manual
Maintenance Analysis Procedures
3-27
Maintenence Analysis Procedures
b. Type the user ID and password obtained in
MAP 0000: Start
MAP
.
c. Type the IP address of the management server running the first
instance of the SAN management application in the
Network
Address
field.
d. Click
Login
. The application opens and the main window
displays.
Was the maintenance action successful?
NO YES
↓ The management server connection is restored and the
second management server is a client. Exit MAP.
Contact the next level of support. Exit MAP.
21
The IP address defining the product to the SAN management
application is incorrect or unknown and must be verified. An
asynchronous RS-232 modem cable and maintenance terminal
(desktop or notebook PC) with a Windows-based operating system
and RS-232 serial communication software (such as ProComm Plus
or HyperTerminal) are required. To verify the IP address:
a. Using a Phillips screwdriver, remove the protective cap from the
9-pin maintenance port. Connect one end of the RS-232 modem
cabletotheport.
b. Connect the other cable end to a 9-pin serial communication port
(COM1 or COM2) at the rear of the maintenance terminal PC.
c. Power on the maintenance terminal. At the Windows desktop,
click
Start
at the left side of the task bar. The
Windows
Workstation
menu displays.
d. At the
Windows Workstation
menu, sequentially select the
Programs
,
Accessories
,
Communications
, and
HyperTerminal
options. The
Connection Description
dialog box displays.
e. Type a descriptive product name in the
Name
field and click
OK
.
The
Connect To
dialog box displays.
f. Ensure the
Connect using
field displays COM1 or COM2
(depending on the port connection to the product), and click
OK
.
The
COMn Properties
dialog box displays, where
n
is 1 or 2.