Service manual

3-14
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
3
As indicated by visual inspection or an event code, one or more
power supplies failed and must be replaced (
RRP: Power Supply
on
page 5-23).
The procedure is concurrent and performed while the product is
operational.
Perform a data collection as part of FRU removal and
replacement.
NOTE: Do not remove a power supply unless a replacement FRU is available.
To avoid product overheating, a removed power supply must be replaced
within five minutes.
Was the maintenance action successful?
NO YES
The product is operational. Exit MAP.
Contact the next level of support. Exit MAP.
4
Inspect and verify facility power is within specifications:
One single-phase connection for each power supply.
Input power between 180 and 264 VAC, at least 15 amps.
Input frequency between 47 and 63 Hz.
Is facility power within specifications?
YES NO
Ask the customer to correct the facility power problem. When
corrected, continue to the next step.
5
One or more power supplies are disconnected from facility power,
improperly installed, or failed. Verify power supplies are connected to
facility power.
a. Ensure AC power cords are connected to the rear of the director
and facility power receptacles. If not, connect power cords as
directed by the customer.
b. Ensure facility circuit breakers are on. If not, ask the customer to
set breakers on.