Service manual
Maintenance Analysis Procedures
3-13
Maintenence Analysis Procedures
MAP 0100: Power Distribution Analysis
This MAP describes fault isolation for theproduct power distribution
system, including defective AC power cords or power supplies. The
failure indicator is:
• Failure of the product to power on.
• Event codes observed at the Event Log (EFCM Basic Edition or
Element Manager interface).
1
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
• An illuminated PWR LED (green) or ERR LED (amber) on front
bezel.
• An illuminated LED (green) on active CTP card.
• Illuminated LEDs adjacent to Fibre Channel ports.
• At least one PWR OK LED (green) illuminated on a power
supply.
• Audio emanations and airflow from fans.
Is the product powered on?
YES NO
↓ A power distribution problem is indicated. Go to step 4.
2
Table 3-4 lists event codes, explanations, and MAP steps.
Table 3-4 MAP 100 Event Codes
Event
Code
Explanation Action
200 Power supply AC voltage failure. Go to step 3.
201 Power supply DC voltage failure. Go to step 3.
202 Power supply thermal failure. Go to step 3.
208 Power supply false shutdown. Go to step 3.