Service manual

Maintenance Analysis Procedures
3-11
Maintenence Analysis Procedures
Is a failure indicated?
NO YES
A FRU failure, power-on self-test (POST) failure, link incident,
interswitch link (ISL) problem, fenced E_Port, or segmented
E_Port is indicated. To obtain event codes that identify the
failure, go to step 10.
8
A link incident may have occurred, but the LIN alerts option is not
enabled and the yellow triangle (attention indicator) does not appear.
Inspect the
Link Incident Log
:
a. For the product reporting the problem:
EFCM Basic Edition - Select
Link Incident
from the
Logs
menu at any view. The
Link Incident Log
displays.
Element Manager - Select
Link Incident Log
from the
Logs
menu at any view. The
Link Incident Log
displays.
b. If a link incident occurred, the port number is listed with one of
the following messages.
Link interface incident - implicit incident.
Link interface incident - bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence (NOS)
received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the
current link state.
Did a listed message appear?
NO YES
A Fibre Channel link incident is indicated. Go to
MAP 0500:
Port Failure or Link Incident Analysis
. Exit MAP.
Perform a data collection and contact the next level of support
(
Collecting Maintenance Data
on page 4-32). Exit MAP.