Service manual
Maintenance Analysis Procedures
3-7
Maintenence Analysis Procedures
600 SBAR assembly hot-insertion initiated. No action required.
601 SBAR assembly recognized. No action required.
602 SBAR assembly anomaly detected. No action required.
603 SBAR assembly hot-removal completed. No action required.
604 SBAR assembly failure. Go to MAP 0400.
605 SBAR assembly revision not supported. Go to MAP 0400.
607 Director contains no operational SBAR assemblies. Go to MAP 0400.
608 User initiated SBAR switch-over. No action required.
620 SBAR fan failure. Go to MAP 0400.
621 Failed SBAR fan recovered. No action required.
800 High temperature warning (port module thermal sensor). Go to MAP 0400.
801 Critically hot temperature warning (port module thermal sensor). Go to MAP 0400.
802 Port module shutdown due to thermal violation. Go to MAP 0400.
805 High temperature warning (SBAR assembly thermal sensor). Go to MAP 0400.
806 Critically hot temperature warning (SBAR assembly thermal
sensor).
Go to MAP 0400.
807 SBAR assembly shutdown due to thermal violation. Go to MAP 0400.
810 High temperature warning (CTP thermal sensor). Go to MAP 0400.
811 Critically hot temperature warning (CTP thermal sensor). Go to MAP 0400.
812 CTP card shutdown due to thermal violations. Go to MAP 0400.
850 Switch shutdown due to CTP thermal violations. Go to MAP 0400.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code Explanation Action