Service manual
3-6
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
453 New feature key installed. No action required.
500 Port card hot-insertion initiated. No action required.
501 Port card recognized. No action required.
502 Port module anomaly detected. No action required.
503 Port card hot-removal completed. No action required.
504 Port module card failure. Go to MAP 0500.
505 Port module revision not supported. Go to MAP 0500.
506 Fibre Channel port failure. Go to MAP 0500.
507 Loopback diagnostics port failure. Go to MAP 0500.
508 Fibre Channel port anomaly detected. No action required.
510 Optical transceiver hot-insertion initiated. No action required.
512 Optical transceiver nonfatal error. Go to MAP 0500.
513 Optical transceiver hot-removal completed. No action required.
514 Optical transceiver failure. Go to MAP 0500
515 Optical digital diagnostics warning threshold exceeded. Go to MAP 0500.
516 Optical digital diagnostics alarm threshold exceeded. Go to MAP 0500.
523 FL_Port open request failed. No action required.
524 No AL_PA acquired. No action required.
525 FL_Port arbitration timeout. No action required.
581 Implicit incident. Go to MAP 0500.
582 Bit error threshold exceeded. Go to MAP 0500.
583 Loss of signal or loss of synchronization. Go to MAP 0500.
584 Not operational primitive sequence received. Go to MAP 0500.
585 Primitive sequence timeout. Go to MAP 0500.
586 Invalid primitive sequence received for current link state. Go to MAP 0500.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code Explanation Action