Service manual

3-4
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
151 Fabric configuration failure. Go to
Collecting Maintenance Data on page 4–32
.
200 Power supply AC voltage failure. Go to MAP 0100.
201 Power supply DC voltage failure. Go to MAP 0100.
202 Power supply thermal failure. Go to MAP 0100.
203 Power supply AC voltage recovery. No action required.
204 Power supply DC voltage recovery. No action required.
206 Power supply removed. Replace FRU.
207 Power supply installed. No action required.
208 Power supply false shutdown. Go to MAP 0100.
300 Cooling fan propeller failed. Go to MAP 0400.
301 Cooling fan propeller failed. Go to MAP 0400.
302 Cooling fan propeller failed. Go to MAP 0400.
303 Cooling fan propeller failed. Go to MAP 0400.
304 Cooling fan propeller failed. Go to MAP 0400.
305 Cooling fan propeller failed. Go to MAP 0400.
310 Cooling fan propeller recovered. No action required.
311 Cooling fan propeller recovered. No action required.
312 Cooling fan propeller recovered. No action required.
313 Cooling fan propeller recovered. No action required.
314 Cooling fan propeller recovered. No action required.
315 Cooling fan propeller recovered. No action required.
320 Fan module removed. Replace FRU.
321 Fan module installed. No action required.
370 Cooling fan status polling temporarily disabled. Go to MAP 0400.
400 Power-up diagnostic failure. Go to MAP 0200.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code Explanation Action