Service manual
2
2-58
Intrepid® 6140 Director Installation and Service Manual
Installation Tasks
f. At the NPIV field, check (enable) or uncheck (disable) N_Port
identifier virtualization. NPIV allows multiple (up to 256)
Fibre Channel addresses to be assigned to a node (N_Port).
3. Click Activate to save the information and close the dialog box.
4. Set the director online (Setting the Director Online or Offline on
page 4-36).
Configure Fabric Parameters
Perform this procedure to configure fabric operating parameters.
1. Set the director offline (SettingtheDirectorOnlineorOfflineon
page 4-36).
2. Select Operating Parameters and Fabric Parameters from the
Configure menu at any view. The Configure Fabric Parameters
dialog box displays (Figure 2-29).
Figure 2-29 Configure Fabric Parameters Dialog Box
a. At the R_A_TOV field, type a value between 10 through 1200
tenths of a second (one through 120 seconds).
NOTE: If the switch is attached to a fabric element, the switch and
element must be setto thesame R_A_TOV value. If thevalues are not
identical, the E_Port connection to the element segments and the
switch cannot communicate with the fabric. In addition, the
R_A_TOV value must be greater than the E_D_TOV value.