Service manual

2
2-38
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Installation Tasks
Task 7: Configure Server Password and Network Addresses
Verify the LAN installation. If the server or Fabricenter equipment
cabinet is installed on a dedicated LAN, network information does
not require change. Change the default password for the server LCD
panel (if required by the customer), then go to Task 8: Configure
Management Server Information.
If the server or equipment cabinet is installed on a public LAN, the
default password for the server LCD panel and the following
transmission control protocol internet protocol (TCP/IP) network
information must be changed to conform to the customer’s LAN
addressing scheme:
•IP address.
•Subnet mask.
Configure Password
To configure a new LCD panel password:
1. Press ENTER at the management server LCD panel . The
Welcome!! or operational information message changes to an
Input Password 0**** message.
2. Using the button to increment a digit, the button to
decrement a digit, the button to move the cursor left, and the
button to move the cursor right, input the default password
(9999), and press ENTER. A LAN 1 Setting?? message appears at
the LCD panel.
3. Press the button several times until the Change Password?
option appears at the LCD panel, then press ENTER. A New
Password 0**** message appears.
4. Use the arrow keys as described in step 2 to input a new 4-digit
numeric password, then press ENTER. A Save Change? Yes,
Save!! message appears.
5. Press ENTER. A Wait a moment! message appears at the LCD
panel, the LCD panel returns to the LAN 1 Setting?? message,
and the password changes.