Task 6: Unpack, Inspect, and Install the Management Server
2-35
Installation Tasks
11. Select Exit from the File pull-down menu. A HyperTerminal
message box appears.
12. Click Yes. A second message box appears.
13. Click No to exit and close the application.
14. Power off the maintenance terminal and disconnect the RS-232
modem cable. Replace the protective cap over the maintenance
port.
15. At the product front panel, press and hold the RESET button for
ten seconds to perform a POR.
16. Connect the product to the customer-supplied Ethernet LAN
segment or Ethernet hub:
a. Connect one end of the Ethernet patch cable (supplied) to the
RJ-45 connector (labelled 10/100).
b. Connect the remaining end of the cable to the LAN as directed
by the customer or to any available Ethernet hub port.
17. Perform one of the following:
— If the product is delivered separately from the management
server, go to Task 6: Unpack, Inspect, and Install the Management
Server.
— If the product is delivered as part of a Fabricenter equipment
cabinet, go to Task 7: Configure Server Password and Network
Addresses.
Task 6: Unpack, Inspect, and Install the Management Server
The management server is rack-mount unit with SAN management
and Element Manager applications installed. The server also includes
a TightVNC Viewer client-server software control package that
provides remote network access (through a standard web browser) to
the server desktop. For information, refer to www.tightvnc.com.
NOTE: The server and related applications provide a GUI to monitor and
manage products, and are a dedicated solution that should not be used for
other tasks. Applications on the server are tested, but not compatibility tested
with other third-party software. Modifications to the server hardware or
installation of additional software (including patches or service packs) may
interfere with normal operation.