Service manual

A
A-16
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Event Code Tables
Event Code: 084
Message: Continuous Incident Detection and Reporting - threshold was exceeded for the port
Severity: Informational.
Explanation: CIDR threshold value exceeded for one of the following incidents
Unroutable Frames Incident - Port has received unroutable frames
Routable Good Frames Incident - Port has received frames with embedded port as destination
Invalid Transmission words Incident - Port has received invalid transmission words
The CIDR reason code is indicated in the event data.
Action: Helps in identifying the misbehaving device, so that it could be corrected/fixed
Event Data: The first byte of event data (byte 0) specifies the port number. The second byte (byte 1) specifies the inactive
reason code as follows:
1 = Unroutable Frames Incident - The port has received unroutable frames.
2 = Good Frames Incident - The port has received frames with embedded port as destination.
3 = Invalid Transmission Words Incident - The port has received invalid transmission words.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔