McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Removal and Replacement Procedures
Figure 5-2 Redundant Power Supply Removal and Replacement
5. Inspect the Event Log:
— At a web browser communicating with the EFCM Basic
Edition interface, select Event from the Logs menu.
— At the management server (Element Manager application),
select Event Log from the Logs menu.
The following event codes appear:
• 200 - Power supply AC voltage failure (recorded when power
is disconnected).
• 206 - Power supply removed.
Replacement To replace a redundant power supply:
1. Remove the replacement power supply from its packaging.
2. Connect the power supply adapter cord to the threaded output
jack at the rear of the switch chassis as shown in Figure 5-2. Twist
the cord clockwise to lock and secure the connection.
3. Connect the AC power cord to a facility power source.
4. Wait several seconds, then inspect the power supply to ensure the
amber LED extinguishes. If the LED illuminates, go to MAP 0000:
Start MAP to isolate the problem.