Service manual
5
5-6
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Removal and Replacement Procedures
b. Open the Port List View. Verify that port Operational State,
Type, Health Status, and Transceiver are correct.
— At the management server (Element Manager application),
open the Hardware View:
a. Ensure alert symbols do not appear (yellow triangle or red
diamond).
b. Double-click the port graphic to open the Port Properties
dialog box. Verify port information is correct.
c. Right-click the port graphic and select Port Technology from
the menu. The Port Technology dialog box displays. Verify
the port technology is correct.
If a problem is indicated, go to MAP 0000: Start MAP to isolate the
problem.
9. Restore communication to the port as directed by the customer.
Refer to Blocking or Unblocking a Port (EFCM Basic Edition) or
Blocking or Unblocking a Port (SAN management application) for
instructions. Inform the customer the port is available.
10. Clear the system error LED on the product front bezel:
— At a web browser communicating with the EFCM Basic
Edition interface, select Clear System Error Light from the
Maintenance menu.
— At the management server (Element Manager application),
open the Hardware View. Right-click the front panel bezel
graphic (away from a FRU), then click the Clear System Error
Light menu selection.
11. If necessary, close and lock the equipment cabinet door.