Service manual
5
RRP 1: SFP Optical Transceiver
5-3
Removal and Replacement Procedures
RRP 1: SFP Optical Transceiver
Use the following procedures to remove or replace a small form
factor pluggable (SFP) optical transceiver. A list of required tools is
provided.
Tools Required The following tools are required:
• Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
• Protective cap (provided with the fiber-optic jumper cable).
• Loopback plug (provided with the product).
• Fiber-optic cleaning kit.
• ESD grounding cable and wrist strap.
Removal To remove an SFP optical transceiver:
1. Inform the customer the port with the defective transceiver will
be blocked. Ensure the system administrator sets any attached
device offline.
2. If the product is not rack-mounted, go to step 3. If the product is
rack-mounted, perform one of the following:
— If the product is installed in an FC-512 Fabricenter equipment
cabinet, insert the 5/16-inch door tool into the socket hole at
the right top of the door (front or rear). Turn the tool counter-
clockwise to unlock and open the door.
— If the product is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet door (front or rear) as
directed by the customer representative.
3. Identify the defective port transceiver from:
— An illuminated amber LED adjacent to the port.
— At a web browser communicating with the EFCM Basic
Edition interface, port failure information displayed at the
Hardware View, Port List View, or Event Log.
— At the management server (Element Manager application),
port failure information displayed at the Hardware View, Port
List View, Port Properties dialog box, or Event Log.