Service manual
4
4-32
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Repair Information
— Primitive sequence timeout.
— Invalid primitive sequence received for current link state.
Refer to MAP 0500: Port Failure or Link Incident Analysis for corrective
actions.
Port Threshold Alert
Log
The Port Threshold Alert Log records a history of threshold alert
notifications. The log describes:
• Date/Time - Date and time the alert occurred.
• Name - Alert name as configured through the Configure Threshold
Alerts dialog box.
• Port - Port number where the alert occurred.
• Type - Alert type: transmit (Tx) or receive (Rx).
• Utilization % - Percent of traffic capacity used and the threshold
value configured through the Configure Threshold Alerts dialog
box. A value of 25 means an alert occurs when throughput
reaches 25% of port capacity.
• Interval - Time interval during which throughput is measured
and an alert can generate. Set through the Configure Threshold
Alerts dialog box.
Security Log The security log displays the following security information:
• Severity - The severity level of the event (informational, warning,
or fatal).
• User - The user associated with the event.
• Reason - The reason code for the event or conditions that caused
the failure.
• Description - The security event category. The information also
includes the description and details of the event and the IP
address of the product.
• Date/Time - The date and time that the event occurred. The
format is yyyy/mm/dd hh:mm:ss:tt. The last two characters
(hundredth of seconds) are needed due to possible higher
frequency rate of some of the advanced logs.
• Count - The number of times that the same event occurs.
• Category - The category.
• IP - The IP address.