Service manual

4
4-6
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Repair Information
Figure 4-1 Clean Fiber-Optic Components
4. Gently wipe the end-face and other surfaces of the component
with an alcohol pad (part 2 of Figure 4-1). Ensure the pad makes
full contact with the surface to be cleaned. Wait approximately
five seconds for cleaned surfaces to dry.
5. Repeat steps two and three (second cleaning).
6. Repeat steps two and three (third cleaning).
7. Reconnect the fiber-optic cable to the optical transceiver.
Download Firmware or Software from the Filecenter
The firmware version shipped with the product is provided on the
System Version XX.YY.ZZ CD-ROM. The SAN management
application (software) shipped with the product is provided on the
EFC Management Applications CD-ROM. Subsequent (upgrade)
firmware and software versions are provided to customers through
the McDATA Filecenter.
NOTE: When upgrading firmware or software, follow all procedural
information contained in release notes or engineering change (EC)
instructions that accompany the version. Such information supplements
information provided in this general procedure.
Download the firmware or software version to the hard drive of a
server with Internet access. This server can be the rack-mount
management server or PC communicating with the EFCM Basic
Edition interface.
To download a firmware or software version use the following steps: