3
MAP 0500: Port Failure or Link Incident Analysis
3-31
Maintenence Analysis Procedures
c. Select McDATA Fabric 1.0 or Open Fabric 1.0 from the Interop
Mode drop-down list.
—Select McDATA Fabric 1.0 if the product is attached only to
other McDATA directors or switches operating in McDATA
Fabric 1.0 mode.
—Select Open Fabric 1.0 if the product is attached to
directors or switches produced by open-fabric compliant
original equipment manufacturers (OEMs).
d. Click OK or Activate.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
6
A loopback (wrap) plug is connected to the port with no diagnostic
running. Remove the plug from the port receptacle. If directed by the
customer, connect a fiber-optic jumper cable attaching a device to the
product.
• If the port is operational with no device attached, both LEDs
adjacent to the port extinguish and the port state is No Light.
• If the port is operational with a device attached, the green LED
illuminates, the amber LED extinguishes, and the port state is
Online.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
7
An ISL connection is not allowed because E_Port capability is
disabled. Install the full-fabric PFE key to enable E_port capability.
Refer to Installing PFE Keys (Optional) (EFCM Basic Edition) or Tas k
16: Configure PFE Key (Optional) (Element Manager). Exit MAP.