MAP 0100: Power Distribution Analysis
3-11
Maintenence Analysis Procedures
1
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
An illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Is the product powered on?
YES NO
A power distribution problem is indicated. Go to step 4.
2
Tab le 3 - 4 lists event codes, explanations, and MAP steps.
3
As indicated by visual inspection or event code 200 or 201, one or
both power supplies failed and must be disconnected and replaced.
Refer to RRP 2: Redundant Power Supply.
The procedure is concurrent and performed while the product is
operational.
Perform a data collection as part of FRU removal and
replacement. Refer to Collecting Maintenance Data (EFCM
Basic Edition) or Collecting Maintenance Data (Element
Manager).
Was the maintenance action successful?
NO YES
The product is operational. Exit MAP.
Contact the next level of support. Exit MAP.
Table 3-4 MAP 100 Event Codes
Event
Code
Explanation Action
200 Power supply AC voltage failure. Go to step 3.
201 Power supply DC voltage failure. Go to step 3.