Service manual
3
Quick Start
3-3
Maintenence Analysis Procedures
071 Switch is isolated. Go to MAP 0600.
072 E_Port connected to unsupported switch. Go to MAP 0600.
073 Fabric initialization error. Go to Collecting Maintenance Data. (EFCM Basic)
or Collecting Maintenance Data (Element
Manager).
074 ILS frame delivery error threshold exceeded. Go to Collecting Maintenance Data. (EFCM Basic)
or Collecting Maintenance Data (Element
Manager).
075 E_Port segmentation recovery. No action required.
080 Unauthorized worldwide name. Go to MAP 0500.
081 Invalid attachment. Go to MAP 0500
082 Port fenced. Go to MAP 0600.
083 Port set to inactive state. Go to MAP 0500
120 Error detected while processing system management command. Go to Collecting Maintenance Data. (EFCM Basic)
or Collecting Maintenance Data (Element
Manager).
121 Zone set activation failed - zone set too large. Reduce size of zone set and retry.
140 Congestion detected on an ISL. Go to MAP 0600.
141 Congestion relieved on an ISL. No action required.
142 Low BB_Credit detected on an ISL. Go to MAP 0600.
143 Low BB_Credit relieved on an ISL. No action required.
150 Fabric merge failure. Go to MAP 0600.
151 Fabric configuration failure. Go to Collecting Maintenance Data. (EFCM Basic)
or Collecting Maintenance Data (Element
Manager).
200 Power supply AC voltage failure. Go to MAP 0100.
201 Power supply DC voltage failure. Go to MAP 0100.
203 Power supply AC voltage recovery. No action required.
204 Power supply DC voltage recovery. No action required.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code
Explanation Action