McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Installation Tasks
Enable EFCM Basic
Edition and Telnet
Access
Follow the procedure in this section to enable EFCM Basic Edition
interface and Telnet access through the maintenance port.
To enable EFCM Basic Edition interface and Telnet access through
the maintenance port using the Element Manager, use the following
steps:
1. Select Authentication from the Security menu
(Security>Authentication). The Configure Authentication window
appears.
2. Select Enable Web Server/Enable Telnet Access in the window.
3. Click Add to add users who will be permitted to have EFCM Basic
Edition interface / Telnet access. The Add/Edit user window
appears.
4. Type the User ID and Password of the user to be added. Confirm
the password in the Retype field. Click OK to return to the
Configure Authentication Window.
5. Click Apply. The Security Change Confirmation Status - Users
window appears.
6. Click Start to apply the settings.
Configure, Enable,
and Test E-mail
Notification
Follow the procedure in this section to configure, enable, and test
e-mail and simple mail transfer protocol (SMTP) addresses to receive
event notifications. Configuration and test are performed at the SAN
management application. E-mail notification is enabled at the
Element Manager application. To perform the procedures:
1. Select Email from the Monitor menu (Monitor>Event
Notification>Email). The Email Event Notification Setup dialog box
appears (Figure 2-34).