Product guide
continues to flow through the network link but is no longer routed through the Sensor. Once the
Sensor resumes normal operation, the switch returns to the "on" state, once again enabling in-line
monitoring.
Sensor outage breaks the link connecting the devices on either side of the Sensor for a brief moment
and requires the renegotiation of the network link between the two peer devices connected to the
Sensor. Depending on the network equipment, this disruption introduced by the renegotiation of the link
layer between the two peer devices might range from a couple of seconds to more than a minute with
certain vendors' devices.
A very brief link disruption might also occur while the links between the Sensor and each of the peer
devices are renegotiated to place the Sensor back in in-line mode. This outage, again, varies depending
on the device, and can range from a few seconds to more than a minute.
You can find the installation and troubleshooting instructions for the kit in the guide that accompanies
the kit. For example, for more information on the Optical kit, see the standard Gigabit Optical
Fail-Open Bypass Kit Guide.
See also
Ports on page 10
Attaching Cables to the Sensor
How does the fail-open function work
4
McAfee
®
Network Security Platform M-3050/M-4050 Sensor Product Guide
33