Installation guide

McAfee® Network Security Platform 6.0
Cabling the heartbeat connection
Important notes
The monitoring ports and failover ports use the same GBIC. (There is no special GBIC
required for the heartbeat connection.)
All GBICs and fiber optic cables are sold separately from the Sensors.
Note : McAfee only officially supports GBICs purchased from McAfee price list.
Cabling guidelines and examples
The following is a quick summary of the rules for cabling the heartbeat connection:
The cabling must always cross the Tx and Rx channels between the Sensor heartbeat
ports. It is for this reason the I-1200 and I-1400 Sensors, for example, require a
crossover cable between their failover pairs.
When 2 ports are used on each Sensor for the heartbeat connection, you must always
cable between identical port names. For example, port 2A on Sensor 1 should always
be cabled to port 2A on Sensor 2 (not 2B).
Some sample hardware requirements and setup hints are given in the following sections:
I-1200 and I-1400 examples
A pair of I-1200 or I-1400 Sensors located within 100 meters or less of each other would
require:
One (1) CAT 5 crossover cable
Connect the crossover cable to each response port.
I-2700 examples
A pair of I-2700 Sensors located within 550 meters of each other would require:
Two (2) standard SX GBICs
One (1) SX fiber optic cable with SC connectors
You need 2 GBICs and a single cable because I-2700 Sensors only use port 4A for
Sensor-to-Sensor communication.