User`s guide
Universal Library User's Guide Analog Input Boards - USB-1208 Series
88
Pacing Hardware pacing, internal clock supported.
External clock supported via the SYNC pin.
Triggering
Trigger functions and methods supported
UL: cbSetTrigger()
UL for .NET: SetTrigger()
Trigger argument values
TrigType USB-1208LS
TRIGHIGH and TRIGLOW
USB-1208FS
TRIGPOSEDGE and TRIGNEGEDGE
Both products support external digital (TTL) hardware triggering. Use the Trig_In
input for the external trigger signal.
Analog output
Analog output functions and methods supported
UL: cbAOut(), cbAOutScan()
UL for .NET: AOut(), AOutScan()
Analog output argument values
Options USB-1208LS
Ignored
USB-1208FS
BACKGROUND, CONTINUOUS
For the USB-1208FS, the number of samples (Count) in a CONTINUOUS scan needs
to be an integer multiple of the packet size (32).
HighChan 0 to 1
Count USB-1208LS
(HighChan – LowChan) + 1
USB-1208FS
Count must be an integer multiple of the number of channels in the scan. In a
CONTINUOUS scan, Count must be an integer multiple of the packet size (32).
Rate USB-1208LS
Ignored
USB-1208FS
Up to 10 kHz maximum for a single channel
Up to 5 kHz maximum for two channels
Performance varies when operating on systems other than Windows XP or
Windows Vista.
Range USB-1208LS