User`s guide

Universal Library User's Guide Analog Input Boards - PCM- and PC-CARD-DAS16 Series
77
Rate Ignored
Count 2 max
Range Ignored - Not programmable; fixed at BIP10VOLTS (±10 V)
For PC-CARD-DAS16/12AO and PCM-DAS16D/12AO, the following argument
values are also valid:
BIP10VOLTS
BIP5VOLTS
DataValue 0 to 4095
For PC-CARD-DAS16/16AO, the following argument values are also valid:
0 to 65535 (Refer to "16-bit values using a signed integer data type" on page 16.)
Digital I/O
Digital I/O functions and methods supported
UL: cbDOut(), cbDIn(), cbDBitIn(), cbDBitOut(), cbDConfigPort()
UL for .NET: DOut(), DIn(), DBitIn(), DBitOut(), DConfigPort()
Digital I/O argument values
PortNum PC-CARD-DAS16/xxAO
FIRSTPORTA
All others in this series:
FIRSTPORTA, FIRSTPORTB
DataValue PC-CARD-DAS16/xxAO
0 to 15 for FIRSTPORTA
All others in this series:
0 to 15 for FIRSTPORTA or FIRSTPORTB
BitNum PC-CARD-DAS16/xxAO
0 to 3 for FIRSTPORTA
All others in this series:
0 to 7 for FIRSTPORTA
Counter I/O
Counter functions and methods supported
UL: cbC8254Config(), cbCIn(), cbCLoad()
UL for .NET: C8254Config(), CIn(), CLoad()
Counter argument values
CounterNum 1 to 3
Config HIGHONLASTCOUNT, ONESHOT, RATEGENERATOR, SQUAREWAVE, SOFTWARESTROBE,
HARDWARESTROBE
LoadValue 0 to 65535 (Refer to "16-bit values using a signed integer data type" on page 16 for
information on 16-bit values using unsigned integers.)
RegNum: LOADREG1, LOADREG2, LOADREG3