User`s guide
Universal Library User's Guide Analog Input Boards - CIO-DAS800 Series
63
CIO-DAS800 Series
Analog input
Analog input functions and methods supported
UL: cbAIn(), cbAInScan(), cbATrig(), cbFileAInScan()
UL for .NET: AIn(), AInScan(), ATrig(), FileAInScan()
Analog input argument values
Options BACKGROUND, CONTINUOUS, EXTCLOCK, CONVERTDATA, SINGLEIO, BLOCKIO,
EXTTRIGGER
HighChan 0 to 7
Rate CIO-DAS802/16
100000
All others in series
50,000
Range CIO-DAS800
Ignored - Not programmable.
CIO-DAS801 supports the following A/D ranges
BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI1VOLTS
BIP1VOLTS UNIPT1VOLTS
BIPPT5VOLTS UNIPT01VOLTS
BIPPT05VOLTS
BIPPT01VOLTS
CIO-DAS802 supports the following A/D ranges
BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
BIPPT625VOLTS
CIO-DAS802/16 supports the following A/D ranges
BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
Analog Output
These boards do not have D/A converters and do not support analog output functions.
Digital I/O
Digital I/O functions and methods supported
UL: cbDOut(), cbDIn(), cbDBitIn(), cbDBitOut()
UL for .NET: DOut(), DIn(), DBitIn(), DBitOut()
Digital I/O argument values
PortNum AUXPORT (not configurable for these boards)
DataValue cbDOut() cbDIn()
0 to 15 0 to 7
BitNum cbDOut() cbDIn()
0 to 3 0 to 2