User`s guide
Universal Library User's Guide Analog Input Boards - PCIM-DAS1602 and PCIM-DAS16JR Series
60
PCIM-DAS1602 and PCIM-DAS16JR Series
Analog input
Analog input functions and methods supported
UL: cbAIn(), cbAInScan(),cbFileAInScan(), cbATrig()
UL for .NET: AIn(), AInScan(),FileAInScan(),ATrig()
Analog input argument values
Options BACKGROUND, CONTINUOUS, EXTCLOCK, CONVERTDATA, SINGLEIO, BLOCKIO,
BURSTMODE, EXTTRIGGER
HighChan 0 to 15 in single-ended mode, 0 to 7 in differential mode
Rate 100000
Range BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
Analog output (PCIM-DAS1602/16 only)
Analog output functions and methods supported
UL: cbAOut(), cbAOutScan()
UL for .NET: AOut(), AOutScan()
Analog output argument values
Options Ignored
HighChan 1 max
Count 2
Rate Ignored
Range Ignored - Not programmable
DataValue 0 to 4095
Digital I/O
Digital I/O functions and methods supported
UL: cbDOut(), cbDIn(), cbDBitIn(), cbDBitOut()
UL for .NET: DOut(), DIn(), DBitIn(), DBitOut()
The PCIM-DAS1602/16 also supports:
UL: cbDConfigPort()
UL for .NET: DConfigPort()