User`s guide

Universal Library User's Guide Counter Boards - INT32 Series
167
INT32 Series
Counter I/O
Counter functions and methods supported
UL: cbC8536Config(), cbC8536Init(), cbCIn(), cbCLoad()
UL for .NET: C8536Config(), C8536Init(), CIn(), CLoad()
Counter argument values
CounterNum 1 to 6
ChipNum 1 or 2
RegName LOADREG1 through LOADREG6
LoadValue Values up to 65,535 (2
16
1) can be used. Refer to "Basic signed integers" on page
164 for more information.
Digital I/O
Digital I/O functions and methods supported
UL: cbDIn(), cbDOut(), cbDBitIn(), cbDBitOut(), cbDConfigPort()
UL for .NET: DIn(), DOut(), DBitIn(), DBitOut(), DConfigPort()
Digital I/O argument values
PortNum FIRSTPORTA, FIRSTPORTB, FIRSTPORTCL, SECONDPORTA, SECONDPORTB and
SECONDPORTCL.
DataValue 0 to 255 using PORTA or PORTB
0 to 15 using PORTCL
BitNum 0 to 39 using FIRSTPORTA
Hardware considerations
Argument Value vs. configuration
These boards have two 8536 chips, which have both counter and digital I/O and interrupt vectoring
capabilities. The numbers stated for digital I/O apply when both chips are configured for the maximum
number of digital devices. The numbers stated for counter I/O apply when both chips are configured for the
maximum number of counter devices.