User`s guide
Universal Library User's Guide Digital Output Boards - CIO-RELAY Series
161
CIO-RELAY Series
Digital I/O
Digital output functions and methods supported
UL: cbDOut, cbDBitOut()
UL for .NET: DOut, DBitOut()
Digital output argument values
PortNum FIRSTPORTA
For CIO-RELAY16 & 16/M, the following argument values are also valid:
FIRSTPORTB
For CIO-RELAY24, the following argument values are also valid:
SECONDPORTA
For CIO-RELAY32, the following argument values are also valid:
SECONDPORTB
DataValue 0 to 255
BitNum 0 to 7 using FIRSTPORTA
For CIO-RELAY16 & 16/M, the following argument values are also valid:
0 to 15 using FIRSTPORTA
For CIO-RELAY24, the following argument values are also valid:
0 to 23 using FIRSTPORTA
For CIO-RELAY32, the following argument values are also valid:
0 to 31 using FIRSTPORTA