User`s guide
Universal Library User's Guide Analog Output Boards - USB-3100 Series
137
USB-3100 Series
The USB-3100 Series includes the USB-3101, USB-3102, USB-3103, USB-3104, USB-3105, USB-3106,
USB-3110, USB-3112, and USB-3114 devices.
Analog output
Analog output functions and methods supported
UL: cbAOut(), cbAOutScan()
UL for .NET: AOut(), AOutScan()
Analog output argument ranges
Options SIMULTANEOUS (cbAOutScan() / AOutScan() only)
HighChan USB-3101, USB-3102, and USB-3110: 0 to 3
USB-3103, USB-3104, and USB-3112: 0 to 7
USB-3105, USB-3106, and USB-3114: 0 to 15
Rate Ignored
Count HighChan – LowChan + 1 max
Range Ignored - Not programmable; selectable for BIP10VOLTS (±10 V), UNI10VOLTS
(0 to 10 V), or MA0TO20 (0 to 20 mA) via InstaCal
USB-3102, USB-3104, USB-3106:
Also selectable for MA0TO20 (0 to 20mA) via InstaCal
DataValue 0 to 65535 (Refer to "16-bit values using a signed integer data type" on page 16.)
Digital I/O
Configuration functions, methods, and argument values supported
UL: cbDConfigBit(), cbDConfigPort()
UL for .NET: DConfigBit(), DConfigPort()
PortNum AUXPORT
PortType AUXPORT
Port I/O functions, methods, and argument values supported
UL: cbDOut(), cbDIn()
UL for .NET: DOut(), DIn()
PortNum AUXPORT
DataValue 0 to 255 for AUXPORT
Bit I/O functions, methods, and argument values supported
UL: cbDBitIn(), cbDBitOut()
UL for .NET: DBitIn(), DBitOut()
PortType AUXPORT
BitNum 0 to 7 on AUXPORT