Halt - Stop display of data and enter Halt mode.
Clear - Clear the main display window.
Display [Options]
None - Disables all message parsing and display activities. Use this
option along with “Open Log File for Write” to maximize pod
recording memory utilization.
Start, Stop, Ack, NAck and R/W - Controls display of I
2
C events.
Start Time, Byte Time, and Bit Rate - Controls display of
message timing information.
Filtering - Enables Slave Address and Message Data filtering. See
Address Map dialog and Message Data dialog for information on
establishing filtering parameters.
Abs Time - Message Start, Byte, and Bit timing can be displayed in
Relative Time or Absolute Time mode.
Relative Time Mode
Relative Mode displays timing information relative to the previous
I
2
C Bus event. Displayed Start timing is the time since the previous
Stop. Displayed Byte or Bit timing is the time since the previous
Start, Byte, or Bit event.