Datasheet

16
4.2.6 Assign a default Run Page <RPn>
Format :
<RPn> Denotes the command for assign a default run page, This page will be
shown if no any schedule is playing
<,R, P &> Are ASCII characters “<”,”R”,”P” & “>”
n The Page no. that will be set as default run i.e.
A = Page A
B = Page B
:
Z = Page Z
4.2.7 Assign Display Brightness level <BX>
Format :
<BX> Denotes the command for assign Display Brightness level
<,B &> Are ASCII characters “<”,”B” & “>”
X The Brightness level.
A = 100%
B = 75%
C = 50%
D = 25%
4.2.8 Change factory default European char table
Format: <Fsxy>…(8 bytes data)
<Fsxy> denotes font size and character position in the European char table.
<F&> are ASCII characters ‘<’, ‘F’ and ‘>’
s: A = Font 5(width)x7(height)
B = Font 6x7
C= Font 4x7
xy: In the range from 00 to 3F
Note: The beginning character position for changeable characters
is <U40> in the table. xy=00 represents position <U40>,
xy=01 represents position <U41>, and so on.
Following the <Fsxy> is 8 bytes character font data. The font data byte is aligned to
the left. Each byte data is taken from left to right horizontally. If the font high is
less than 8, the font data is padded with 00(Hexadecimal) up to 8 bytes data.
.
<RPn>
<BX>