Manual

- 5 -
MAINTENANCE
WARNING
Always exercise the stopping procedure before
servicing or lubricating the unit.
After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.
CAUTION
Always verify fluid levels and check for leaks after
changing fluids.
Do not drain oil onto ground, into open streams,
or down sewage drains.
Maintenance Schedule
1. Check all hardware after the first 5 hours of use, then follow the maintenance schedule.
Fluid Levels
1. MBW #01058 ---- 6-Pack (8 oz bottles)
MBW #17320---- 1 quart (32 oz)
Changing Exciter Oil
Refer to Exciter, page 14.
1. Support the roller over a drain pan and remove the
drain plug (#22)
2. Reinstall the drain plug with thread sealing
compound.
3. Clean the area around the vent adapter (#17) and
remove it.
4. Made sure exciter is level and fill oil specified in Fluid
level chart.
5. Reinstall vent adapter and vent plug with thread
sealing compound.
Replacing Shockmounts
1. Remove the unit from the excavator, support blade
with blocks, and chock the wheel so the attachment
is secure, stable, and upright.
2. Remove the four 1-1/2” bolts securing the upper and
lower weldments of the machine.
3. Separate the halves of the Machine with a suitable
lifting device, taking care not to overstrain the
hydraulic hoses.
SYSTEM MAINTENANCE Daily
EVERY 50
HOURS
EVERY 250
HOURS
YEARLY
Drum hubs Grease X
Exciter Check oil level X
Check for oil leaks X
Change oil XX
Tighten Bolts
1
XX
Hardware
Check and tighten as needed
1
XX
Shockmounts Check for cracks or tears XX
SYSTEM FLUID VOLUME RECOMMENDED OIL
Exciter 17 oz
MBW Ground Pounder
®
Exciter Oil
1
Engine Refer to engine operator/owner manual