User manual
Page 5
Wiring scheme for balanced Input/Parallel-Out XLR Audio Connectors (male / female)
Signal “ ”, out-of-phase or “COLD”
Signal “ ”, in-phase or “HOT”
Shield wire,
-
+
31
2
XLR Input
Connector
on
MB Loudspeaker
Signal out-of-phase connected to SLEEVE
Signal in-phase connected to TIP
Shield wire,
31
2
Not connected
Sleeve
Tip
Example wiring scheme when only unbalanced signal source is available
(different wiring scheme could be suggested depending on the specific situation)
Unbalanced signal source
Attached to this manual is part of manufacturer documentation for Neutrik PowerCon,
where you can find mechanical and electrical details how to assemble this connector.
Wiring scheme for
Neutrik PowerCon
(internal side view)
N (Neutral)
L (Live)
(Ground)
PowerCon Insertion
Removal